Back to top

Free Shipping!

Factory Prices

Customer Service Award

Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments

Roll over image to zoom in

Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments

Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments

PCE Instruments - PCE-CTI 10

New product

€456.21  RRP-7%

€420.11  VAT incl. €341.56 VAT excl.

Free shipping 5 to 9 working days


Description and specifications

  • Clamp meter, ideal for measuring voltages up to 1500 V AC/DC and currents up to 1000 A AC/DC.
  • VFD (Variable Frequency Driver) measurement with frequency from 45 Hz to 1 kHz.
  • Bluetooth 4.0.
  • Data logging with memory for 16 groups and 100 000 values.
    • The data is stored with date and time.
  • 2.36" TFT screen.

Technical data:

  • 38 mm horizontal clamp.
  • 63 mm vertical clamp.
  • 45 mm aperture.
  • IP65 protection.
  • Degree of contamination 2.
  • CAT IV 600 V, CAT III 1000 V and CAT II 1500 V categories.
  • Maximum altitude of 2000 m / 6562 ft.
  • Lithium battery, 7.4 V and 1200 mAh.
  • Input Output 100 to 240 V AC, 50 to 60 Hz, 12 V DC and 2 A.
  • Reference conditions 18 to 28 °C and 64 to 82 °F; <80 % R.H. without condensation.
  • Operating conditions 5 to 40 °C and 41 to 104 °F <80 % R.H. without condensation.
  • Storage conditions -20 to 60 °C and -4 to 140 °F and <80 % R.H. without condensation.
  • The dimensions are 100 mm wide, 275 mm high and 45 mm deep.
  • Weight 481 g.

DC voltage range

  • ±600.0 mV.
    • Resolution of 0.1 mV.
    • Accuracy ±(0,8 % of value + 8 digits).
  • ±6,000 V,
    • Resolution of 0.001 V.
    • Accuracy ±(0,5 % of value + 5 digits).
  • ±60,00 V.
    • Resolution of 0.01 V.
    • Accuracy ±(0,5 % of value + 5 digits).
  • ±600,0 V.
    • 0.1 V resolution.
    • Accuracy ±(0,8 % of value + 5 digits).
  • ±1500 V.
    • 1 V resolution.
    • Accuracy ±(0,8 % of value + 5 digits).
  • Input impedance of >10 MΩ.
  • Overvoltage protection: 1500 VDC and 1000 VAC rms.

AC voltage range

  • 0.000 to 6.000 V.
    • Resolution of 0.001 V.
  • 0.00 to 60.00 V.
    • Resolution of 0.01 V.
  • 0.0 to 600.0 V.
    • 0.1 V resolution.
  • 0 to 1500 V.
    • 1 V resolution.
  • The accuracy is applicable between 10 and 100 % of the respective measurement and a sine wave.
  • Input impedance of >9 MΩ.
  • 1000 V DC/AC RMS overvoltage protection.
  • The accuracy of the "PEAK" function is ±10 % of the value.
    • The response time is 1 ms.
  • Accuracy at 50 to 60 Hz of ±(1,2 % of the value + 5 digits).
  • Accuracy in 61 to 1 kHz of ±(2,5 % of the value + 5 digits).

AC voltage range with small input impedance (LowZ)

  • 0.000 to 6.000 V.
    • Resolution of 0.001 V.
  • 0.00 to 60.00 V.
    • Resolution of 0.01 V.
  • 0.0 to 300.0 V.
    • 0.1 V resolution.
  • Input impedance 300 kΩ.
  • Overvoltage protection is 1000 VDC / VAC RMS.
  • The accuracy is applicable between 10 and 100 % of the respective measurement and a sine wave.
  • Accuracy ±(3,0 % of value + 40 digits).

DC and AC voltage range (50 to 1 kHz)

  • 0.000 to 6.000 V.
    • Resolution of 0.001 V.
  • 0.00 to 60.00 V.
    • Resolution of 0.01 V.
  • 0.0 to 600.0 V.
    • 0.1 V resolution.
  • 0 to 1000 V.
    • 1 V resolution.
  • Input impedance is 300 kΩ.
  • 1000 VDC / VAC RMS overvoltage protection.
  • Accuracy ±(2,5 % of value + 40 digits).

DC and AC voltage range with small input impedance (LowZ)

  • 0.000 to 6.000 V.
    • Resolution of 0.001 V.
  • 0.00 to 60.00 V.
    • Resolution of 0.01 V.
  • 0.0 to 300.0 V.
    • 0.1 V resolution.
  • Input impedance 300 kΩ.
  • 1000 VDC / VAC RMS overvoltage protection.
  • Accuracy ±(3,5 % of the value + 40 digits).

Non-contact voltage detector (NCV)

  • 100 to 1000 AC/DC.

Direct current range

  • 60,00 A.
    • Resolution of 0.01 A.
  • 600,0 A.
    • 0.1 A resolution.
  • 1000 A.
    • Resolution 1 A.
  • 1000 A AC/DC overvoltage protection.
  • Accuracy ±(3,0 % of value + 8 digits).

DC current range (50 to 60 Hz).

  • 0.00 to 60.00 A.
    • Resolution of 0.01 A.
  • 0.0 to 600.0 A.
    • 0.1 A resolution.
  • 0 to 1000 A.
    • 1 A resolution.
  • 1000 A AC/DC overvoltage protection.
  • The accuracy is applicable between 10 and 100 % of the respective measurement and a sine wave.
  • The starting current is for reference only.
  • Accuracy ±(2,5 % of the value + 5 digits).

Resistance range and continuity test

  • 0.0 to 600.0 Ω.
    • Resolution of 0.1 Ω.
    • Accuracy ±(1,0 % of value + 10 digits).
  • 0,000 to 6,000 kΩ.
    • Resolution of 0.001 kΩ.
    • Accuracy ±(0,8 % of value + 5 digits).
  • 0,00 to 60,00 kΩ.
    • Resolution of 0.01 kΩ.
    • Accuracy ±(0,8 % of value + 5 digits).
  • 0.0 to 600.0 kΩ.
    • Resolution of 0.1 kΩ.
    • Accuracy ±(0,8 % of value + 5 digits).
  • 0,000 to 6,000 MΩ.
    • Resolution of 0.001 MΩ.
    • Accuracy ±(0,8 % of value + 5 digits).
  • 0.00 to 60.00 MΩ.
    • Resolution of 0.01 MΩ.
    • Accuracy ±(2,5 % of value + 10 digits).
  • Acoustic signal at <50 Ω continuity test.
  • 1000 A AC/DC overvoltage protection.

Frequency range

  • 0.00 to 60.00 Hz.
    • Resolution of 0.01 Hz.
  • 0.0 to 600.0 Hz.
    • Resolution of 0.1 Hz.
  • 0.000 to 6.000 kHz.
    • Resolution of 0.001 kHz.
  • 0.00 to 60.00 kHz.
    • Resolution of 0.01 kHz.
  • 0.0 to 600.0 kHz.
    • 0.1 kHz resolution.
  • 0,000 to 6,000 MH.
    • Resolution of 0.001 MHz.
  • 1000 A AC/DC overvoltage protection.
  • Sensitivity:
    • >2 Vrms with a duty cycle between 20 and 80 % and a frequency <100 kHz.
    • >5 Vrms with a duty cycle between 20 ... 80 % and a frequency >100 kHz.
  • Accuracy ±(0,2 % of value + 5 digits).

Duty cycle

  • 10,0 a 90,0 %.
    • Resolution of 0.1 %.
    • Accuracy ±(1,2 % of the value + 8 digits).
  • frequency from 40 to 10 kHz.
  • Pulse width of ±5 V with a duration between 100 µs and 100 mS.

Capacity

  • Accuracy from 0.00 to 60.00 nF.
    • 0.01 nF.
    • Resolution ±(3,0 % of the value + 20 digits).
  • Accuracy from 0.0 to 600.0 nF.
    • 0.1 nF.
    • Resolution ±(3,0 % of the value + 8 digits).
  • Accuracy from 0.000 to 6.000 µF.
    • 0.001 µF.
    • Resolution ±(3,0 % of the value + 8 digits).
  • Accuracy from 0.00 to 60.00 µF.
    • 0.01 µF.
    • Resolution ±(3,0 % of the value + 8 digits).
  • Accuracy from 0.0 to 600.0 nF.
    • 0.1 nF.
    • Resolution ±(3,0 % of the value + 8 digits).
  • Accuracy from 0 to 6000 µF.
    • 1 µF.
    • Resolution ±(3,5 % of the value + 20 digits).
  • Accuracy from 0.00 to 60.00 mF.
    • 0.01 mF.
    • Resolution for reference only.
  • Accuracy 0.0 to 600.0 mF.
    • 0.1 mF.
    • Resolution for reference only.
  • 1000 A AC/DC overvoltage protection.

Temperature range with thermocouple type K

  • -40.0 to 600.0 °C.
    • Resolution 0.1 °C.
    • Accuracy ±(1.5 % of value + 3 °C).
  • 600 to 1000 °C.
    • 1 °C resolution.
    • Accuracy ±(1.5 % of value + 3 °C).
  • -40.0 to 600.0°F.
    • Resolution 0.1 °F.
    • Accuracy ±(1.5 % of value + 5.4 °F).
  • 600 to 1800 °F.
    • 1 °F resolution.
    • Accuracy ±(1.5 % of value + 5.4 °F).
  • 245.0 to 600.0 K.
    • Resolution of 0.1 K.
    • Accuracy ±(1.5 % of value + 3 K).
  • 600 to 1273 K.
    • 1 K resolution.
    • Accuracy ±(1.5 % of value + 3 K).
  • 1000 A AC/DC overvoltage protection.

Diode test

  • Test current <1.5 mA.
  • Maximum voltage of 3.3 VDC.

Payment methods

Visa MasterCard American Express Wire transfer
Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments

Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments

€420.11  VAT incl.

€420.11  VAT incl.

Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments

Product details - Clamp meter for electrical measurements 1500 V AC DC CTI 10 PCE Instruments

Product description:

  • Clamp meter, ideal for measuring voltages up to 1500 V AC/DC and currents up to 1000 A AC/DC.
  • VFD (Variable Frequency Driver) measurement with frequency from 45 Hz to 1 kHz.
  • Bluetooth 4.0.
  • Data logging with memory for 16 groups and 100 000 values.
    • The data is stored with date and time.
  • 2.36" TFT screen.

Technical data:

  • 38 mm horizontal clamp.
  • 63 mm vertical clamp.
  • 45 mm aperture.
  • IP65 protection.
  • Degree of contamination 2.
  • CAT IV 600 V, CAT III 1000 V and CAT II 1500 V categories.
  • Maximum altitude of 2000 m / 6562 ft.
  • Lithium battery, 7.4 V and 1200 mAh.
  • Input Output 100 to 240 V AC, 50 to 60 Hz, 12 V DC and 2 A.
  • Reference conditions 18 to 28 °C and 64 to 82 °F; <80 % R.H. without condensation.
  • Operating conditions 5 to 40 °C and 41 to 104 °F <80 % R.H. without condensation.
  • Storage conditions -20 to 60 °C and -4 to 140 °F and <80 % R.H. without condensation.
  • The dimensions are 100 mm wide, 275 mm high and 45 mm deep.
  • Weight 481 g.

DC voltage range

  • ±600.0 mV.
    • Resolution of 0.1 mV.
    • Accuracy ±(0,8 % of value + 8 digits).
  • ±6,000 V,
    • Resolution of 0.001 V.
    • Accuracy ±(0,5 % of value + 5 digits).
  • ±60,00 V.
    • Resolution of 0.01 V.
    • Accuracy ±(0,5 % of value + 5 digits).
  • ±600,0 V.
    • 0.1 V resolution.
    • Accuracy ±(0,8 % of value + 5 digits).
  • ±1500 V.
    • 1 V resolution.
    • Accuracy ±(0,8 % of value + 5 digits).
  • Input impedance of >10 MΩ.
  • Overvoltage protection: 1500 VDC and 1000 VAC rms.

AC voltage range

  • 0.000 to 6.000 V.
    • Resolution of 0.001 V.
  • 0.00 to 60.00 V.
    • Resolution of 0.01 V.
  • 0.0 to 600.0 V.
    • 0.1 V resolution.
  • 0 to 1500 V.
    • 1 V resolution.
  • The accuracy is applicable between 10 and 100 % of the respective measurement and a sine wave.
  • Input impedance of >9 MΩ.
  • 1000 V DC/AC RMS overvoltage protection.
  • The accuracy of the "PEAK" function is ±10 % of the value.
    • The response time is 1 ms.
  • Accuracy at 50 to 60 Hz of ±(1,2 % of the value + 5 digits).
  • Accuracy in 61 to 1 kHz of ±(2,5 % of the value + 5 digits).

AC voltage range with small input impedance (LowZ)

  • 0.000 to 6.000 V.
    • Resolution of 0.001 V.
  • 0.00 to 60.00 V.
    • Resolution of 0.01 V.
  • 0.0 to 300.0 V.
    • 0.1 V resolution.
  • Input impedance 300 kΩ.
  • Overvoltage protection is 1000 VDC / VAC RMS.
  • The accuracy is applicable between 10 and 100 % of the respective measurement and a sine wave.
  • Accuracy ±(3,0 % of value + 40 digits).

DC and AC voltage range (50 to 1 kHz)

  • 0.000 to 6.000 V.
    • Resolution of 0.001 V.
  • 0.00 to 60.00 V.
    • Resolution of 0.01 V.
  • 0.0 to 600.0 V.
    • 0.1 V resolution.
  • 0 to 1000 V.
    • 1 V resolution.
  • Input impedance is 300 kΩ.
  • 1000 VDC / VAC RMS overvoltage protection.
  • Accuracy ±(2,5 % of value + 40 digits).

DC and AC voltage range with small input impedance (LowZ)

  • 0.000 to 6.000 V.
    • Resolution of 0.001 V.
  • 0.00 to 60.00 V.
    • Resolution of 0.01 V.
  • 0.0 to 300.0 V.
    • 0.1 V resolution.
  • Input impedance 300 kΩ.
  • 1000 VDC / VAC RMS overvoltage protection.
  • Accuracy ±(3,5 % of the value + 40 digits).

Non-contact voltage detector (NCV)

  • 100 to 1000 AC/DC.

Direct current range

  • 60,00 A.
    • Resolution of 0.01 A.
  • 600,0 A.
    • 0.1 A resolution.
  • 1000 A.
    • Resolution 1 A.
  • 1000 A AC/DC overvoltage protection.
  • Accuracy ±(3,0 % of value + 8 digits).

DC current range (50 to 60 Hz).

  • 0.00 to 60.00 A.
    • Resolution of 0.01 A.
  • 0.0 to 600.0 A.
    • 0.1 A resolution.
  • 0 to 1000 A.
    • 1 A resolution.
  • 1000 A AC/DC overvoltage protection.
  • The accuracy is applicable between 10 and 100 % of the respective measurement and a sine wave.
  • The starting current is for reference only.
  • Accuracy ±(2,5 % of the value + 5 digits).

Resistance range and continuity test

  • 0.0 to 600.0 Ω.
    • Resolution of 0.1 Ω.
    • Accuracy ±(1,0 % of value + 10 digits).
  • 0,000 to 6,000 kΩ.
    • Resolution of 0.001 kΩ.
    • Accuracy ±(0,8 % of value + 5 digits).
  • 0,00 to 60,00 kΩ.
    • Resolution of 0.01 kΩ.
    • Accuracy ±(0,8 % of value + 5 digits).
  • 0.0 to 600.0 kΩ.
    • Resolution of 0.1 kΩ.
    • Accuracy ±(0,8 % of value + 5 digits).
  • 0,000 to 6,000 MΩ.
    • Resolution of 0.001 MΩ.
    • Accuracy ±(0,8 % of value + 5 digits).
  • 0.00 to 60.00 MΩ.
    • Resolution of 0.01 MΩ.
    • Accuracy ±(2,5 % of value + 10 digits).
  • Acoustic signal at <50 Ω continuity test.
  • 1000 A AC/DC overvoltage protection.

Frequency range

  • 0.00 to 60.00 Hz.
    • Resolution of 0.01 Hz.
  • 0.0 to 600.0 Hz.
    • Resolution of 0.1 Hz.
  • 0.000 to 6.000 kHz.
    • Resolution of 0.001 kHz.
  • 0.00 to 60.00 kHz.
    • Resolution of 0.01 kHz.
  • 0.0 to 600.0 kHz.
    • 0.1 kHz resolution.
  • 0,000 to 6,000 MH.
    • Resolution of 0.001 MHz.
  • 1000 A AC/DC overvoltage protection.
  • Sensitivity:
    • >2 Vrms with a duty cycle between 20 and 80 % and a frequency <100 kHz.
    • >5 Vrms with a duty cycle between 20 ... 80 % and a frequency >100 kHz.
  • Accuracy ±(0,2 % of value + 5 digits).

Duty cycle

  • 10,0 a 90,0 %.
    • Resolution of 0.1 %.
    • Accuracy ±(1,2 % of the value + 8 digits).
  • frequency from 40 to 10 kHz.
  • Pulse width of ±5 V with a duration between 100 µs and 100 mS.

Capacity

  • Accuracy from 0.00 to 60.00 nF.
    • 0.01 nF.
    • Resolution ±(3,0 % of the value + 20 digits).
  • Accuracy from 0.0 to 600.0 nF.
    • 0.1 nF.
    • Resolution ±(3,0 % of the value + 8 digits).
  • Accuracy from 0.000 to 6.000 µF.
    • 0.001 µF.
    • Resolution ±(3,0 % of the value + 8 digits).
  • Accuracy from 0.00 to 60.00 µF.
    • 0.01 µF.
    • Resolution ±(3,0 % of the value + 8 digits).
  • Accuracy from 0.0 to 600.0 nF.
    • 0.1 nF.
    • Resolution ±(3,0 % of the value + 8 digits).
  • Accuracy from 0 to 6000 µF.
    • 1 µF.
    • Resolution ±(3,5 % of the value + 20 digits).
  • Accuracy from 0.00 to 60.00 mF.
    • 0.01 mF.
    • Resolution for reference only.
  • Accuracy 0.0 to 600.0 mF.
    • 0.1 mF.
    • Resolution for reference only.
  • 1000 A AC/DC overvoltage protection.

Temperature range with thermocouple type K

  • -40.0 to 600.0 °C.
    • Resolution 0.1 °C.
    • Accuracy ±(1.5 % of value + 3 °C).
  • 600 to 1000 °C.
    • 1 °C resolution.
    • Accuracy ±(1.5 % of value + 3 °C).
  • -40.0 to 600.0°F.
    • Resolution 0.1 °F.
    • Accuracy ±(1.5 % of value + 5.4 °F).
  • 600 to 1800 °F.
    • 1 °F resolution.
    • Accuracy ±(1.5 % of value + 5.4 °F).
  • 245.0 to 600.0 K.
    • Resolution of 0.1 K.
    • Accuracy ±(1.5 % of value + 3 K).
  • 600 to 1273 K.
    • 1 K resolution.
    • Accuracy ±(1.5 % of value + 3 K).
  • 1000 A AC/DC overvoltage protection.

Diode test

  • Test current <1.5 mA.
  • Maximum voltage of 3.3 VDC.

Product classification:

This product is found in the category Electrical and Voltage Testing Equipment: digital type, with clamp, ammeters.

SKU: 4250348727558, PCECTI, 10