Three-phase wattmeter and power ammeter with current clamp 360 PCE Instruments
PCE Instruments - PCE-360
New product
Description and specifications
- Three-phase wattmeter and power ammeter (real-time).
- It is used to measure the power in one or three phases.
- The 4-digit LCD display shows up to 10 values.
- Up to four current clamps can be adapted at the same time.
- It has an automatic switch-off function after 30 minutes of inactivity.
- It has a 4 GB SD card for data logging.
- In manual mode, it can store up to 99 values.
- In data logging mode, it stores up to 20000 values (512K memory). Ideal for long-term analysis.
- The waveform can be observed via the software.
- With USB interface, so all values can be transferred to the PC.
- The sampling rate is 1/s.
- Maximum voltage between current and neutral inputs is 1000 Vrms.
- The maximum cable diameter when using the current clamps is Ø 42 mm.
- Power is supplied by eight 1.5 V AA batteries.
- The battery life is approximately 50 hours.
- It is supplied with a 12 V, 300 mA adapter.
- The product is delivered factory calibrated.
- The operating conditions are:
- 0 to +40 °C <80 % Relative humidity (up to +31 °C)
- <50 % relative humidity (+32 to +40 °C).
- The temperature coefficient is 0,1 * (corresponding accuracy) / °C (< +18 o > +28 °C).
- The storage conditions are -10 to +60 °C<70 % relative humidity, non-condensing.
- The dimensions of the measuring device are 117 mm wide, 235 mm high and 54 mm deep.
- The dimensions of the current clamps are 88 mm wide, 193 mm high and 40 mm deep.
- Product weight with batteries 730 g.
- Weight of tweezers 333 g.
- Delivery includes:
- One PCE-360 three-phase power meter.
- Four current clamps (1, 2, 3, 4 with 3 m cable length; 1000 A AC, clamp opening 40 mm).
- Four alligator clips (blue, yellow, red and black, cable length 3 m).
- Four test leads.
- Eight 1.5 V batteries, type AA 1.
- CD-ROM software and USB interface.
- Carrying bag.
- Mains adapter (110 V to 12 V; 220 V to 12 V).
- Instruction manual.
Technical data:
- AC Voltage measurement.
- Measuring range: 50 to 600.0 V actual value.
- Resolution is 0.1 V.
- Accuracy is ±1.5 % measured value + 10 digits.
- The input resistance is 2 MΩ.
- Overload protection is 1000 V rms.
- Nominal mains frequency is 45 to 66 Hz.
- AC Current measurement.
- Measuring range is 3 to 999.9 A real effective value.
- Resolution is 0.1 A.
- The accuracy (incl. current clamp) is ±1.5 % measured value + 15 digits.
- Current clamp output signal is 0.35 mV/A.
- The overload protection is 1000 A rms.
- Nominal mains frequency 45 to 66 Hz.
- Effective power P.
- Measuring range 150 W to 999.9 kW.
- Resolution is 0.1 kW.
- Accuracy is ±1.5 % measured value + 20 digits.
- Apparent power S.
- Measuring range is 150 VA to 999.9 kVA.
- Resolution is 0,1 kVA.
- Accuracy is ±1.5 % measurement value ± 20 digits.
- Reactive power Q.
- Measuring range is 150 var to 999.9 kVar.
- Resolution is 0,1 kvar.
- Accuracy is ±1.5 % measurement value ± 20 digits.
- Power factor (cos Φ).
- Measuring range 0 to +1.
- Resolution 0,001.
- Accuracy ±0.06.
- Phase angle (Φ).
- Measuring range -90° to +90°.
- Resolution 0,1°.
- Accuracy ± 3°.
- Frequency measurement (U > 50V).
- Measuring range 40 to 100 Hz.
- Resolution 0.1 Hz.
- Accuracy ±0.1 % measurement value +2 digits.
- Measurement source is voltage U1 > 10 V.
- Measurement of phase rotation (UL > 50V).
- Input voltage range 3P > 10 V.
- Normal direction of phase rotation is clockwise.
- Reverse direction of phase rotation is counterclockwise.
- Measurement sources are U1, U2 and U3.
- Effective energy or work measurement.
- Measuring range and resolution are 0 to 9999 MWh.
- Accuracy of ±1,5 % measurement value +20 digits.
- Timer interval is 1 second.
- Timer accuracy is ±50 ppm (25° C / 77° F).
- Measurement of apparent energy or work.
- Measurement range and resolution is 0 to 9999 MVAh.
- Accuracy of ±1,5 % measurement value +20 digits.
- Timer interval is 1 second.
- Timer accuracy is ±50 ppm (25° C / 77° F).
- Measurement of reactive energy or reactive work.
- Measurement range and resolution is 0 to 9999 MVArh.
- Accuracy of ±1.5 % measurement value +20 digits.
- Timer interval is 1 second.
- Timer accuracy is ±50 ppm (25° C / 77° F).
- Harmonic measurement.
- Order from 1 to 63.
- Accuracy is ±3 % THD.
- Measurement source is U1, U2, U3 > 10 and V I1, I2, I3 > 3 A.