Back to top

Free Shipping!

Factory Prices

Customer Service Award

Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments

Roll over image to zoom in

Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments
Earth Tester PCE-ET 5000 PCE Instruments

Earth Tester PCE-ET 5000 PCE Instruments

PCE Instruments - PCE-ET 5000

New product

€3,542.28  RRP-14%

€3,012.41  VAT incl. €2,449.12 VAT excl.

Free shipping 4 to 7 working days


Description and specifications

  • This is an earth meter with memory.
  • It is used for various measurements, such as resistance to earth, normal resistance of 2 or 4 wires, resistance of a lightning rod, etc.
  • It has a function for checking connections.
  • Allows mobile use.
  • It integrates a data memory for later analysis on a PC.
  • It has an alarm in case of wrong connection.
  • Measures resistances directly or indirectly.
  • Delivery includes:
    • Meter.
    • 4 crocodile clips.
    • 1 charger.
    • 1 USB cable.
    • 4 Test leads.
    • 1 Voltage cable for clamp.
    • 1 Power cable for clamp.
    • 6 1.5 V C batteries.
    • 2 Current clamps.
    • 1 Rechargeable battery.
    • 4 Spades.
    • Instruction manual.

Technical data:

3-wire earth resistance

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 26 seconds.
  • Probe resistance Rs: <100 kΩ.
  • Auxiliary earth resistance Rh: <100 kΩ.
  • Resolution: 0.001 Ω.
  • Measuring range Re: 0.02 Ω to 300 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.
  • Atmospheric conditions for good accuracy: 0 to 28° C.
  • Response time: <15 seconds.

4-wire earth resistance

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 30 seconds.
  • Probe resistance Rs: <100 kΩ.
  • Auxiliary earth resistance Rh: <100 kΩ.
  • Resolution: 0.001 Ω.
  • Measuring range Re: 0.02 Ω to 300 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.
  • Atmospheric conditions for good accuracy: 0 to 28° C.
  • Response time: <25 seconds.

3-wire earth resistance with current clamp

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 26 seconds.
  • Probe resistance Rs: <100 kΩ.
  • Auxiliary earth resistance Rh: <100 kΩ.
  • Resolution: 0.001 Ω.
  • Measuring range Re: 0.02 Ω to 20 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.
  • Atmospheric conditions for good accuracy: 0 to 28° C.
  • Response time: <25 seconds.

4-wire earth resistance with current clamp

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 26 seconds.
  • Probe resistance Rs: <100 kΩ.
  • Auxiliary earth resistance Rh: <100 kΩ.
  • Resolution: 0.001 Ω.
  • Measuring range Re: 0.02 Ω to 20 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.
  • Atmospheric conditions for good accuracy: 0 to 28° C.
  • Response time: <25 seconds.

Earth resistance with current clamps only

  • Test voltage: 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 26 seconds.
  • Measuring range Re: 0.02 Ω to 150 kΩ.
  • Resolution: 0.001 Ω.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.
  • Atmospheric conditions for good accuracy: 0 to 28° C.
  • Response time: <25 seconds.

Soil resistance

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 26 seconds.
  • Resolution: 0.001 Ω * m.
  • Measuring range Re: 0.02 Ω to 1000 kΩ.
  • Accuracy: ±(5 % + 10 digits).

2-wire resistance measurement (AC)

  • Test voltage: 20 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short circuit current: 250 mA.
  • Test time: 26 seconds.
  • Resolution: 0.001 Ω * m.
  • Measuring range Re: 0.02 Ω to 300 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.

2-wire resistance measurement (DC)

  • Test voltage: 20 V AC.
  • Short circuit current: 250 mA.
  • Test time: 26 seconds.
  • Resolution: 0.001 Ω * m.
  • Measuring range Re: 0.02 Ω to 3 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <3 V.
  • Fst: 16 to 400 Hz.

4-wire resistance measurement (DC)

  • Test voltage: 20 V AC.
  • Short circuit current: 250 mA.
  • Test time: 26 seconds.
  • Resolution: 0.001 Ω * m.
  • Measuring range Re: 0.02 Ω to 3 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <3 V.
  • Fst: 16 to 400 Hz.

Line compensation

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short Circuit Current: 250 mA.
  • Test time: 26 seconds.
  • Resolution: 0.001 Ω * m.
  • Measuring range Re: 0.02 Ω to 30 kΩ.
  • Accuracy: ±(3 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.

Interference voltage

  • Measuring range:
    • ±50 V DC.
    • 1 to 50 V AC.
  • Resolution: 0,1 V.
  • Accuracy: ±(5 % + 5 digits).

Interference current

  • Measuring range: 20 mA to 2 A.
  • Resolution: 1 mA.
  • Accuracy: ±(5 % + 5 digits).

Interference frequency

  • Measuring range: 16 to 400 Hz.
  • Resolution: 1 Hz.
  • Accuracy: ±(1 % + 10 digits).

Payment methods

Visa MasterCard American Express Wire transfer
Earth Tester PCE-ET 5000 PCE Instruments

Earth Tester PCE-ET 5000 PCE Instruments

€3,012.41  VAT incl.

€3,012.41  VAT incl.

Earth Tester PCE-ET 5000 PCE Instruments

Product details - Earth Tester PCE-ET 5000 PCE Instruments

Product description:

  • This is an earth meter with memory.
  • It is used for various measurements, such as resistance to earth, normal resistance of 2 or 4 wires, resistance of a lightning rod, etc.
  • It has a function for checking connections.
  • Allows mobile use.
  • It integrates a data memory for later analysis on a PC.
  • It has an alarm in case of wrong connection.
  • Measures resistances directly or indirectly.
  • Delivery includes:
    • Meter.
    • 4 crocodile clips.
    • 1 charger.
    • 1 USB cable.
    • 4 Test leads.
    • 1 Voltage cable for clamp.
    • 1 Power cable for clamp.
    • 6 1.5 V C batteries.
    • 2 Current clamps.
    • 1 Rechargeable battery.
    • 4 Spades.
    • Instruction manual.

Technical data:

3-wire earth resistance

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 26 seconds.
  • Probe resistance Rs: <100 kΩ.
  • Auxiliary earth resistance Rh: <100 kΩ.
  • Resolution: 0.001 Ω.
  • Measuring range Re: 0.02 Ω to 300 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.
  • Atmospheric conditions for good accuracy: 0 to 28° C.
  • Response time: <15 seconds.

4-wire earth resistance

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 30 seconds.
  • Probe resistance Rs: <100 kΩ.
  • Auxiliary earth resistance Rh: <100 kΩ.
  • Resolution: 0.001 Ω.
  • Measuring range Re: 0.02 Ω to 300 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.
  • Atmospheric conditions for good accuracy: 0 to 28° C.
  • Response time: <25 seconds.

3-wire earth resistance with current clamp

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 26 seconds.
  • Probe resistance Rs: <100 kΩ.
  • Auxiliary earth resistance Rh: <100 kΩ.
  • Resolution: 0.001 Ω.
  • Measuring range Re: 0.02 Ω to 20 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.
  • Atmospheric conditions for good accuracy: 0 to 28° C.
  • Response time: <25 seconds.

4-wire earth resistance with current clamp

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 26 seconds.
  • Probe resistance Rs: <100 kΩ.
  • Auxiliary earth resistance Rh: <100 kΩ.
  • Resolution: 0.001 Ω.
  • Measuring range Re: 0.02 Ω to 20 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.
  • Atmospheric conditions for good accuracy: 0 to 28° C.
  • Response time: <25 seconds.

Earth resistance with current clamps only

  • Test voltage: 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 26 seconds.
  • Measuring range Re: 0.02 Ω to 150 kΩ.
  • Resolution: 0.001 Ω.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.
  • Atmospheric conditions for good accuracy: 0 to 28° C.
  • Response time: <25 seconds.

Soil resistance

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short-circuit current: 250 mA.
  • Test time: 26 seconds.
  • Resolution: 0.001 Ω * m.
  • Measuring range Re: 0.02 Ω to 1000 kΩ.
  • Accuracy: ±(5 % + 10 digits).

2-wire resistance measurement (AC)

  • Test voltage: 20 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short circuit current: 250 mA.
  • Test time: 26 seconds.
  • Resolution: 0.001 Ω * m.
  • Measuring range Re: 0.02 Ω to 300 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.

2-wire resistance measurement (DC)

  • Test voltage: 20 V AC.
  • Short circuit current: 250 mA.
  • Test time: 26 seconds.
  • Resolution: 0.001 Ω * m.
  • Measuring range Re: 0.02 Ω to 3 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <3 V.
  • Fst: 16 to 400 Hz.

4-wire resistance measurement (DC)

  • Test voltage: 20 V AC.
  • Short circuit current: 250 mA.
  • Test time: 26 seconds.
  • Resolution: 0.001 Ω * m.
  • Measuring range Re: 0.02 Ω to 3 kΩ.
  • Accuracy: ±(5 % + 10 digits).
  • Ust: <3 V.
  • Fst: 16 to 400 Hz.

Line compensation

  • Test voltage: 20, 48 V AC.
  • Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
  • Short Circuit Current: 250 mA.
  • Test time: 26 seconds.
  • Resolution: 0.001 Ω * m.
  • Measuring range Re: 0.02 Ω to 30 kΩ.
  • Accuracy: ±(3 % + 10 digits).
  • Ust: <24 V.
  • Fst: 16 to 400 Hz.

Interference voltage

  • Measuring range:
    • ±50 V DC.
    • 1 to 50 V AC.
  • Resolution: 0,1 V.
  • Accuracy: ±(5 % + 5 digits).

Interference current

  • Measuring range: 20 mA to 2 A.
  • Resolution: 1 mA.
  • Accuracy: ±(5 % + 5 digits).

Interference frequency

  • Measuring range: 16 to 400 Hz.
  • Resolution: 1 Hz.
  • Accuracy: ±(1 % + 10 digits).

Product classification:

This product is found in the category Electrical and Voltage Testing Equipment: digital type, with clamp.

SKU: 4250348719126, PCEET, 5000