- This is an earth meter with memory.
- It is used for various measurements, such as resistance to earth, normal resistance of 2 or 4 wires, resistance of a lightning rod, etc.
- It has a function for checking connections.
- Allows mobile use.
- It integrates a data memory for later analysis on a PC.
- It has an alarm in case of wrong connection.
- Measures resistances directly or indirectly.
- Delivery includes:
- Meter.
- 4 crocodile clips.
- 1 charger.
- 1 USB cable.
- 4 Test leads.
- 1 Voltage cable for clamp.
- 1 Power cable for clamp.
- 6 1.5 V C batteries.
- 2 Current clamps.
- 1 Rechargeable battery.
- 4 Spades.
- Instruction manual.
Technical data:
3-wire earth resistance
- Test voltage: 20, 48 V AC.
- Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
- Short-circuit current: 250 mA.
- Test time: 26 seconds.
- Probe resistance Rs: <100 kΩ.
- Auxiliary earth resistance Rh: <100 kΩ.
- Resolution: 0.001 Ω.
- Measuring range Re: 0.02 Ω to 300 kΩ.
- Accuracy: ±(5 % + 10 digits).
- Ust: <24 V.
- Fst: 16 to 400 Hz.
- Atmospheric conditions for good accuracy: 0 to 28° C.
- Response time: <15 seconds.
4-wire earth resistance
- Test voltage: 20, 48 V AC.
- Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
- Short-circuit current: 250 mA.
- Test time: 30 seconds.
- Probe resistance Rs: <100 kΩ.
- Auxiliary earth resistance Rh: <100 kΩ.
- Resolution: 0.001 Ω.
- Measuring range Re: 0.02 Ω to 300 kΩ.
- Accuracy: ±(5 % + 10 digits).
- Ust: <24 V.
- Fst: 16 to 400 Hz.
- Atmospheric conditions for good accuracy: 0 to 28° C.
- Response time: <25 seconds.
3-wire earth resistance with current clamp
- Test voltage: 20, 48 V AC.
- Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
- Short-circuit current: 250 mA.
- Test time: 26 seconds.
- Probe resistance Rs: <100 kΩ.
- Auxiliary earth resistance Rh: <100 kΩ.
- Resolution: 0.001 Ω.
- Measuring range Re: 0.02 Ω to 20 kΩ.
- Accuracy: ±(5 % + 10 digits).
- Ust: <24 V.
- Fst: 16 to 400 Hz.
- Atmospheric conditions for good accuracy: 0 to 28° C.
- Response time: <25 seconds.
4-wire earth resistance with current clamp
- Test voltage: 20, 48 V AC.
- Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
- Short-circuit current: 250 mA.
- Test time: 26 seconds.
- Probe resistance Rs: <100 kΩ.
- Auxiliary earth resistance Rh: <100 kΩ.
- Resolution: 0.001 Ω.
- Measuring range Re: 0.02 Ω to 20 kΩ.
- Accuracy: ±(5 % + 10 digits).
- Ust: <24 V.
- Fst: 16 to 400 Hz.
- Atmospheric conditions for good accuracy: 0 to 28° C.
- Response time: <25 seconds.
Earth resistance with current clamps only
- Test voltage: 48 V AC.
- Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
- Short-circuit current: 250 mA.
- Test time: 26 seconds.
- Measuring range Re: 0.02 Ω to 150 kΩ.
- Resolution: 0.001 Ω.
- Accuracy: ±(5 % + 10 digits).
- Ust: <24 V.
- Fst: 16 to 400 Hz.
- Atmospheric conditions for good accuracy: 0 to 28° C.
- Response time: <25 seconds.
Soil resistance
- Test voltage: 20, 48 V AC.
- Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
- Short-circuit current: 250 mA.
- Test time: 26 seconds.
- Resolution: 0.001 Ω * m.
- Measuring range Re: 0.02 Ω to 1000 kΩ.
- Accuracy: ±(5 % + 10 digits).
2-wire resistance measurement (AC)
- Test voltage: 20 V AC.
- Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
- Short circuit current: 250 mA.
- Test time: 26 seconds.
- Resolution: 0.001 Ω * m.
- Measuring range Re: 0.02 Ω to 300 kΩ.
- Accuracy: ±(5 % + 10 digits).
- Ust: <24 V.
- Fst: 16 to 400 Hz.
2-wire resistance measurement (DC)
- Test voltage: 20 V AC.
- Short circuit current: 250 mA.
- Test time: 26 seconds.
- Resolution: 0.001 Ω * m.
- Measuring range Re: 0.02 Ω to 3 kΩ.
- Accuracy: ±(5 % + 10 digits).
- Ust: <3 V.
- Fst: 16 to 400 Hz.
4-wire resistance measurement (DC)
- Test voltage: 20 V AC.
- Short circuit current: 250 mA.
- Test time: 26 seconds.
- Resolution: 0.001 Ω * m.
- Measuring range Re: 0.02 Ω to 3 kΩ.
- Accuracy: ±(5 % + 10 digits).
- Ust: <3 V.
- Fst: 16 to 400 Hz.
Line compensation
- Test voltage: 20, 48 V AC.
- Test frequency: 94 Hz, 105 Hz, 111 Hz, 128 Hz, AFC.
- Short Circuit Current: 250 mA.
- Test time: 26 seconds.
- Resolution: 0.001 Ω * m.
- Measuring range Re: 0.02 Ω to 30 kΩ.
- Accuracy: ±(3 % + 10 digits).
- Ust: <24 V.
- Fst: 16 to 400 Hz.
Interference voltage
- Measuring range:
- ±50 V DC.
- 1 to 50 V AC.
- Resolution: 0,1 V.
- Accuracy: ±(5 % + 5 digits).
Interference current
- Measuring range: 20 mA to 2 A.
- Resolution: 1 mA.
- Accuracy: ±(5 % + 5 digits).
Interference frequency
- Measuring range: 16 to 400 Hz.
- Resolution: 1 Hz.
- Accuracy: ±(1 % + 10 digits).