Back to top

Free Shipping!

Factory Prices

Customer Service Award

CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments

Roll over image to zoom in

CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments
CM LCD display tester PCE Instruments

CM LCD display tester PCE Instruments

PCE Instruments - PCE-CM 3

New product

€129.78  VAT incl. €105.52 VAT excl.

Free shipping 4 to 7 working days


Description and specifications

  • Fixed aperture clamp meter for AC and DC current, resistance, temperature and capacitance measurements.
  • It integrates a 4000-digit backlit LCD display where the data is displayed.
  • Low battery and, if available, low voltage and overload are also indicated.
  • The clamp has a fixed opening of 17 mm.
  • It also has two measuring tips.
  • It has an automatic switch-off after 30 minutes of non-use.
  • It is powered by two 1.5 V batteries.
  • It is a compact product and therefore ideal for technicians and specialists.
  • Delivery includes 1 ammeter, 2 measuring tips, 2 test leads, 1 thermocouple adapter, 1 thermocouple type K, 2 AAA batteries, and 1 manual.

Technical data:

  • DC voltage measuring range: from 4, 40, 400 and 600 V DC.
    • Accuracy: ± 1.2, 1.5, 1.5 and 2 % of the value plus 2 d, respectively.
    • Resolution: 1, 10 and 100 mV and 1 V, respectively.
    • Input impedance: 10 MΩ.
    • Overvoltage protection: 600 V DC
      and 600 V AC RMS.
  • Measurement range of AC voltage: 4, 40, 400 and 600 V DC.
    • Accuracy: ± 1,2 (+2d); 1,5,; 1,5 and 2 % of the value plus 2 d, respectively.
    • Resolution: 1, 10 and 100 mV and 1 V, respectively.
    • Input impedance: 10 MΩ.
    • Overvoltage protection: 600 V DC
      and 600 V AC RMS.
    • Frequency: 50 to 400 Hz.
  • Measuring range of alternating current: 200 A AC.
    • Accuracy: ± 3,0 % of value + 5 d.
    • Resolution: 100 mA.
    • Overload protection: 200 A AC.
    • Frequency range: 50 to 60 Hz.
  • Resistance measurement range: 400 Ω; 4, 40 and 400 KΩ; 4 and 40 MΩ.
    • Accuracy: 1; 1.5; 1.5; 1.5; 1.5; 2.5; 3.5 % of the value plus 4 d respectively.
    • Resolution: 0.1, 1, 10 Ω; 1 and 10 KΩ respectively.
    • Overload protection: 250 V DC or 250 AC RMS.
  • Frequency measurement range: 40 and 400 Hz; 4, 40 and 400 KHz; 10 MHz.
    • Accuracy: ± 3,0 % of the value + 5 °C or 8 °F.
    • Resolution: 0.01 to 1 °C or °F.
    • Overload protection: 300 V DC and 300 AC RMS.
  • Temperature measuring range: -20 to 760 °C or 4 to 4000 °F.
    • Accuracy: 1; 1.5; 1.5; 1.5; 1.5; 2.5; 3.5 % of the value plus 4 d respectively.
    • Resolution: 0.1, 1, 10 Ω; 1 and 10 KΩ respectively.
    • Overload protection: 250 V DC or 250 AC RMS.
    • Type K connection.
  • Duty cycle measurement range: 0.1 to 99.9 %.
    • Accuracy: ±1,2 % of the value ± 2 d
    • Resolution: 0,01 %.
    • Sensitivity: 1 V RMS.
    • Pulse width: > 100 µs,
    • Overload protection: 300 V DC and 300 AC RMS.
  • Capacitance measuring range: 4, 40 and 400 nF and 4, 40 and 400 µF.
    • Accuracy: ± 5 % of the value over 20 d for 1 nF. For 400 µF ± 3 % of the value + 10 d. The rest ± 3 % of the value over 5 d.
    • Resolution: 0,1; 1; 10 and 100 nF and 1 and 10 µF, respectively.
    • Overload protection: 250 V DC or 250 AC RMS
  • Test function:
    • Diode test: 0.5 mA.
    • Inverse voltage: 1.5 V.
    • Open circuit voltage: 0.5 V.
  • Alert: noise when resistance
  • Updating values: 3 Hz rate.
  • Input impedance: 10 MΩ.
  • Power supply: 2 x 1.5 V AAA batteries.
  • Pollution degree: 2.
  • This current clamp meter complies with the following standards: IEC1010-1 (2001); CAT II 1000 V and CAT III 600 V.

Payment methods

Visa MasterCard American Express Wire transfer
CM LCD display tester PCE Instruments

CM LCD display tester PCE Instruments

€129.78  VAT incl.

€129.78  VAT incl.

CM LCD display tester PCE Instruments

Product details - CM LCD display tester PCE Instruments

Product description:

  • Fixed aperture clamp meter for AC and DC current, resistance, temperature and capacitance measurements.
  • It integrates a 4000-digit backlit LCD display where the data is displayed.
  • Low battery and, if available, low voltage and overload are also indicated.
  • The clamp has a fixed opening of 17 mm.
  • It also has two measuring tips.
  • It has an automatic switch-off after 30 minutes of non-use.
  • It is powered by two 1.5 V batteries.
  • It is a compact product and therefore ideal for technicians and specialists.
  • Delivery includes 1 ammeter, 2 measuring tips, 2 test leads, 1 thermocouple adapter, 1 thermocouple type K, 2 AAA batteries, and 1 manual.

Technical data:

  • DC voltage measuring range: from 4, 40, 400 and 600 V DC.
    • Accuracy: ± 1.2, 1.5, 1.5 and 2 % of the value plus 2 d, respectively.
    • Resolution: 1, 10 and 100 mV and 1 V, respectively.
    • Input impedance: 10 MΩ.
    • Overvoltage protection: 600 V DC
      and 600 V AC RMS.
  • Measurement range of AC voltage: 4, 40, 400 and 600 V DC.
    • Accuracy: ± 1,2 (+2d); 1,5,; 1,5 and 2 % of the value plus 2 d, respectively.
    • Resolution: 1, 10 and 100 mV and 1 V, respectively.
    • Input impedance: 10 MΩ.
    • Overvoltage protection: 600 V DC
      and 600 V AC RMS.
    • Frequency: 50 to 400 Hz.
  • Measuring range of alternating current: 200 A AC.
    • Accuracy: ± 3,0 % of value + 5 d.
    • Resolution: 100 mA.
    • Overload protection: 200 A AC.
    • Frequency range: 50 to 60 Hz.
  • Resistance measurement range: 400 Ω; 4, 40 and 400 KΩ; 4 and 40 MΩ.
    • Accuracy: 1; 1.5; 1.5; 1.5; 1.5; 2.5; 3.5 % of the value plus 4 d respectively.
    • Resolution: 0.1, 1, 10 Ω; 1 and 10 KΩ respectively.
    • Overload protection: 250 V DC or 250 AC RMS.
  • Frequency measurement range: 40 and 400 Hz; 4, 40 and 400 KHz; 10 MHz.
    • Accuracy: ± 3,0 % of the value + 5 °C or 8 °F.
    • Resolution: 0.01 to 1 °C or °F.
    • Overload protection: 300 V DC and 300 AC RMS.
  • Temperature measuring range: -20 to 760 °C or 4 to 4000 °F.
    • Accuracy: 1; 1.5; 1.5; 1.5; 1.5; 2.5; 3.5 % of the value plus 4 d respectively.
    • Resolution: 0.1, 1, 10 Ω; 1 and 10 KΩ respectively.
    • Overload protection: 250 V DC or 250 AC RMS.
    • Type K connection.
  • Duty cycle measurement range: 0.1 to 99.9 %.
    • Accuracy: ±1,2 % of the value ± 2 d
    • Resolution: 0,01 %.
    • Sensitivity: 1 V RMS.
    • Pulse width: > 100 µs,
    • Overload protection: 300 V DC and 300 AC RMS.
  • Capacitance measuring range: 4, 40 and 400 nF and 4, 40 and 400 µF.
    • Accuracy: ± 5 % of the value over 20 d for 1 nF. For 400 µF ± 3 % of the value + 10 d. The rest ± 3 % of the value over 5 d.
    • Resolution: 0,1; 1; 10 and 100 nF and 1 and 10 µF, respectively.
    • Overload protection: 250 V DC or 250 AC RMS
  • Test function:
    • Diode test: 0.5 mA.
    • Inverse voltage: 1.5 V.
    • Open circuit voltage: 0.5 V.
  • Alert: noise when resistance
  • Updating values: 3 Hz rate.
  • Input impedance: 10 MΩ.
  • Power supply: 2 x 1.5 V AAA batteries.
  • Pollution degree: 2.
  • This current clamp meter complies with the following standards: IEC1010-1 (2001); CAT II 1000 V and CAT III 600 V.

Product classification:

This product is found in the category Electrical and Voltage Testing Equipment: digital type, with clamp, ammeters.

SKU: 4250348718259, PCECM, 3